TY - JOUR
T1 - The PHOBOS silicon sensors
AU - Back, Birger
AU - Betts, Russell
AU - Ganz, Rudolf
AU - Gulbrandsen, Kristjan H.
AU - Holzman, Burt
AU - Kucewicz, Wojtek
AU - Lin, Willis T.
AU - Mülmenstädt, Johannes
AU - Van Nieuwenhuizen, Gerrit J.
AU - Nouicer, Rachid
AU - Pernegger, Heinz
AU - Reuter, Michael
AU - Sarin, Pradeep
AU - Tsay, Vincent
AU - Vale, Carla M.
AU - Wadsworth, Bernard
AU - Wuosmaa, Alan
AU - Wyslouch, Bolek
PY - 1999/8
Y1 - 1999/8
N2 - PHOBOS is one of the four experiments at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. PHOBOS almost exclusively utilizes silicon sensors to measure charged particle multiplicity distributions and to track particles in a 2-arm spectrometer. The detector consists of about 450 silicon pad sensors. Nine different pad geometries are used to match the different physics needs of the experiment. A relatively high granularity, of up to 1536 channels per sensor, is used in the spectrometer. The multiplicity detector uses 128 and 64 channel sensors and the charge deposition per pad is measured to determine the multiplicity of single events. All sensors are of the double-metal silicon pad type with pad sizes from 1 cm2 up to 4 cm2. They are produced in Taiwan by the ERSO foundry under supervision of Miracle Co. and National Central University. An extensive testing procedure makes it possible to select sensors suited for use in PHOBOS. Detector modules consisting of up to five sensors are read out with integrated chips of either 64 or 128 channels. The testing of the sensors and the performance of assembled detector modules is discussed.
AB - PHOBOS is one of the four experiments at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. PHOBOS almost exclusively utilizes silicon sensors to measure charged particle multiplicity distributions and to track particles in a 2-arm spectrometer. The detector consists of about 450 silicon pad sensors. Nine different pad geometries are used to match the different physics needs of the experiment. A relatively high granularity, of up to 1536 channels per sensor, is used in the spectrometer. The multiplicity detector uses 128 and 64 channel sensors and the charge deposition per pad is measured to determine the multiplicity of single events. All sensors are of the double-metal silicon pad type with pad sizes from 1 cm2 up to 4 cm2. They are produced in Taiwan by the ERSO foundry under supervision of Miracle Co. and National Central University. An extensive testing procedure makes it possible to select sensors suited for use in PHOBOS. Detector modules consisting of up to five sensors are read out with integrated chips of either 64 or 128 channels. The testing of the sensors and the performance of assembled detector modules is discussed.
UR - http://www.scopus.com/inward/record.url?scp=0033237021&partnerID=8YFLogxK
U2 - 10.1016/S0920-5632(99)00552-6
DO - 10.1016/S0920-5632(99)00552-6
M3 - 期刊論文
AN - SCOPUS:0033237021
SN - 0920-5632
VL - 78
SP - 245
EP - 251
JO - Nuclear Physics B - Proceedings Supplements
JF - Nuclear Physics B - Proceedings Supplements
IS - 1-3
ER -