摘要
This study is based on a general interior lighting installation and discusses the relation between veiling luminance and the unified glare rating. Through curve fitting and a derived formula, a transfer function between veiling luminance and the unified glare rating is generated. This result connects disability glare and discomfort glare within a finite range, where the relation between them is almost linearly dependent. This transfer function has a high accuracy as shown by a comparison between the calculated results and the original data, and is the first to provide a connection between disability glare and discomfort glare.
原文 | ???core.languages.en_GB??? |
---|---|
頁(從 - 到) | 587-592 |
頁數 | 6 |
期刊 | Lighting Research and Technology |
卷 | 46 |
發行號 | 5 |
DOIs | |
出版狀態 | 已出版 - 10月 2014 |