Shear strength of RC jacketed interior beam-column joints without horizontal shear reinforcement

研究成果: 雜誌貢獻期刊論文同行評審

19 引文 斯高帕斯(Scopus)

摘要

The interior joint shear strength of nonductile frames strengthened with reinforced concrete (RC) jackets, but with no new joint shear hoops and no dowel anchors installed into the new and old concrete interface, was investigated experimentally. Seven oneway interior beam-column joint subassemblages were tested under quasistatic cyclic loading to observe the joint shear strength and overall frame performance. The test measurements are also used to verify two of the analytical models used for predicting the horizontal shear strength of jacketed joints without horizontal joint shear reinforcement. The results show that the RC jacketed scheme is able to efficiently rehabilitate nonductile frames with very poor joint details. An empirical equation for calculating the joint shear strength of RC jacketed frames is proposed in this study.

原文???core.languages.en_GB???
頁(從 - 到)222-232
頁數11
期刊ACI Structural Journal
106
發行號2
出版狀態已出版 - 3月 2009

指紋