Novel assessment of temporal variation in fractionated electrograms using histogram analysis of local fractionation interval in patients with persistent atrial fibrillation

Yenn Jiang Lin, Kazuyoshi Suenari, Men Tzung Lo, Chen Lin, Wan Hsin Hsieh, Shih Lin Chang, Li Wei Lo, Yu Feng Hu, Chen Chuan Cheng, Yasuki Kihara, Tze Fan Chao, Beny Hartono, Tsu Juey Wu, Wei Shiang Lin, Ke Hsin Hsu, Ambrose S. Kibos, Norden E. Huang, Shih Ann Chen

研究成果: 雜誌貢獻期刊論文同行評審

8 引文 斯高帕斯(Scopus)

摘要

Background - The characteristics of atrial electrograms associated with atrial fibrillation (AF) termination are controversial. We investigated the electrogram characteristics that indicate procedural AF termination during continuous complex fractionated electrogram ablation. Methods and Results - Fifty-two consecutive patients with persistent AF (47 men; aged 54±9 years), who underwent electrogram-based catheter ablation in the left atrium and coronary sinus after pulmonary vein isolation, were enrolled. The intracardiac bipolar atrial electrogram recordings were characterized by (1) fractionation interval (FI) analysis (>6 seconds), (2) kurtosis (shape of the FI histogram), and (3) skewness (asymmetry of the FI histogram). Sites showing complex, fractionated electrograms (mean FI ≤60 ms) were targeted, and AF was terminated in 20 patients (38%) after the pulmonary vein isolation. The conventional complex fractionated electrogram sites (mean ≤120 ms) in patients with AF termination exhibited higher median kurtosis (2.69 [interquartile range, 2.03-3.46] versus 2.35 [interquartile range, 1.79-2.48]; P=0.024) and higher complex fractionated electrogram-mean interval (102.7±19.8 versus 87.7±15.0; P=0.008) than patients without AF termination. Furthermore, AF termination sites had higher median kurtosis than targeted sites without AF termination (5.13 [interquartile range, 3.51-6.47] versus 4.18 [interquartile range, 2.91-5.34]; P<0.01) in patients with procedural termination. In addition, patients with AF termination had a higher sinus rhythm maintenance rate after a single procedure than patients without AF termination (log-rank test, P=0.007). Conclusions - A kurtosis analysis using the FI histogram may be a useful tool in identifying the critical substrate for persistent AF and potential responders to catheter ablation.

原文???core.languages.en_GB???
頁(從 - 到)949-956
頁數8
期刊Circulation: Arrhythmia and Electrophysiology
5
發行號5
DOIs
出版狀態已出版 - 10月 2012

指紋

深入研究「Novel assessment of temporal variation in fractionated electrograms using histogram analysis of local fractionation interval in patients with persistent atrial fibrillation」主題。共同形成了獨特的指紋。

引用此