摘要
The effectiveness of applying non-thermal plasma for destroying VOCs from gas streams is experimentally investigated. For this study, p-xylene is selected as the target pollutant. Operating parameters investigated include applied voltage, temperature and composition of the gas stream. Results indicate that as high as 100% p-xylene removal efficiencies can be achieved. The end-products are also examined using FTIR. Overall, the results demonstrate the potential for applying non-thermal plasma process as a viable alternate technology for destroying VOCs from gas streams.
原文 | ???core.languages.en_GB??? |
---|---|
頁面 | 6 |
頁數 | 6 |
出版狀態 | 已出版 - 1998 |
事件 | Proceedings of the 1998 91st Annual Meeting & Exposition of the Air & Waste Management Association - San Diego, CA, USA 持續時間: 14 6月 1998 → 18 6月 1998 |
???event.eventtypes.event.conference???
???event.eventtypes.event.conference??? | Proceedings of the 1998 91st Annual Meeting & Exposition of the Air & Waste Management Association |
---|---|
城市 | San Diego, CA, USA |
期間 | 14/06/98 → 18/06/98 |