Measurements of lactate concentration using lactate oxidase and an electrochemical oxygen sensor

E. B. Makovos, C. C. Liu

研究成果: 雜誌貢獻期刊論文同行評審

17 引文 斯高帕斯(Scopus)

摘要

Lactate oxidase was used in combination with an electrochemical dissolved oxygen sensor to measure L‐lactate concentration in the physiological saline solution. The rate of oxygen consumption was found to have an excellent linear relationship with the lactate concentration on a log‐log scale in the lactate concentration range of 0.3–25 mM. This detection does not require additional reagents and can be developed into a simple method of L‐lactate determination. The effects of the temperature and pH of the solution on the reaction rate were investigated and discussed.

原文???core.languages.en_GB???
頁(從 - 到)167-170
頁數4
期刊Biotechnology and Bioengineering
27
發行號2
DOIs
出版狀態已出版 - 2月 1985