Measurement of refractive index variation by differential surface plasmon resonance technique

Ju Yi Lee, Wu Sheng Gu

研究成果: 雜誌貢獻期刊論文同行評審

摘要

A differential detection technique combined with a surface plasmon resonance technique is proposed for refractive index variation measurement. The experimental results demonstrate that our system can attain a resolution of 1. 2 × 10-5 RIU (refractive index unit). In addition, a method for two-dimensional detection of the refractive index variation is demonstrated. The system is free from the influence of optical source fluctuation, and can improve the measurement sensitivity.

原文???core.languages.en_GB???
頁(從 - 到)182-184
頁數3
期刊Optical Review
20
發行號2
DOIs
出版狀態已出版 - 3月 2013