TY - JOUR
T1 - Investigating power density and the degree of nonlinearity in intrinsic components of anesthesia EEG by the hilbert-huang transform
T2 - An example using ketamine and alfentanil
AU - Tsai, Feng Fang
AU - Fan, Shou Zen
AU - Lin, Yi Shiuan
AU - Huang, Norden E.
AU - Yeh, Jia Rong
N1 - Publisher Copyright:
© 2016 Tsai et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2016/12
Y1 - 2016/12
N2 - Empirical mode decomposition (EMD) is an adaptive filter bank for processing nonlinear and non-stationary signals, such as electroencephalographic (EEG) signals. EMD works well to decompose a time series into a set of intrinsic mode functions with specific frequency bands. An IMF therefore represents an intrinsic component on its correspondingly intrinsic frequency band. The word of 'intrinsic' means the frequency is totally adaptive to the nature of a signal. In this study, power density and nonlinearity are two critical parameters for characterizing the amplitude and frequency modulations in IMFs. In this study, a nonlinearity level is quantified using degree of waveform distortion (DWD), which represents the characteristic of waveform distortion as an assessment of the intra-wave modulation of an IMF. In the application of anesthesia EEG analysis, the assessments of power density and DWD for a set of IMFs represent dynamic responses in EEG caused by two different anesthesia agents, Ketamine and Alfentanil, on different frequency bands. Ketamine causes the increase of power density and the decrease of nonlinearity on ã-band neuronal oscillation, which cannot be found EEG responses of group B using Alfentanil. Both agents cause an increase of power density and a decrease of nonlinearity on β-band neuronal oscillation accompany with a loss of consciousness. Moreover, anesthesia agents cause the decreases of power density and nonlinearity (i.e. DWD) for the low-frequency IMFs.
AB - Empirical mode decomposition (EMD) is an adaptive filter bank for processing nonlinear and non-stationary signals, such as electroencephalographic (EEG) signals. EMD works well to decompose a time series into a set of intrinsic mode functions with specific frequency bands. An IMF therefore represents an intrinsic component on its correspondingly intrinsic frequency band. The word of 'intrinsic' means the frequency is totally adaptive to the nature of a signal. In this study, power density and nonlinearity are two critical parameters for characterizing the amplitude and frequency modulations in IMFs. In this study, a nonlinearity level is quantified using degree of waveform distortion (DWD), which represents the characteristic of waveform distortion as an assessment of the intra-wave modulation of an IMF. In the application of anesthesia EEG analysis, the assessments of power density and DWD for a set of IMFs represent dynamic responses in EEG caused by two different anesthesia agents, Ketamine and Alfentanil, on different frequency bands. Ketamine causes the increase of power density and the decrease of nonlinearity on ã-band neuronal oscillation, which cannot be found EEG responses of group B using Alfentanil. Both agents cause an increase of power density and a decrease of nonlinearity on β-band neuronal oscillation accompany with a loss of consciousness. Moreover, anesthesia agents cause the decreases of power density and nonlinearity (i.e. DWD) for the low-frequency IMFs.
UR - http://www.scopus.com/inward/record.url?scp=85005992333&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0168108
DO - 10.1371/journal.pone.0168108
M3 - 期刊論文
C2 - 27973590
AN - SCOPUS:85005992333
SN - 1932-6203
VL - 11
JO - PLoS ONE
JF - PLoS ONE
IS - 12
M1 - e0168108
ER -