@inproceedings{5ced77151cc94f51bd80a1bfb0f50741,
title = "Experimental study of the discharge coefficient of internal openings in partitioned buildings",
abstract = "This experimental study uses wind tunnel experiments to investigate the discharge coefficient and flow rate of wind-driven cross ventilation in partitioned buildings. The discharge coefficients of internal openings under different flow conditions were determined by a fan technique. It is found that the internal discharge coefficient is a function of internal porosity, but independent of external porosity and opening location. Based on the experimental results, a predictive model for the internal pressure of multi-room buildings is developed and verified. This model could be used to predict the flow rate through multi-room buildings once the external pressure distribution and opening areas are known.",
keywords = "Building ventilation, Discharge coefficient, Wind tunnel experiment",
author = "Chu, {Chia R.} and Wang, {Yu Wen}",
year = "2009",
language = "???core.languages.en_GB???",
isbn = "9866717437",
series = "7th Asia-Pacific Conference on Wind Engineering, APCWE-VII",
booktitle = "7th Asia-Pacific Conference on Wind Engineering, APCWE-VII",
note = "7th Asia-Pacific Conference on Wind Engineering, APCWE-VII ; Conference date: 08-11-2009 Through 12-11-2009",
}