摘要
This study uses planar laser-induced fluorescence (PLIF) technique to measure the concentration distribution of single port, horizontally discharged buoyant jets in crossflows. The result of concentration measurement was verified against an independent concentration sampling technique. Dilution of the buoyant jets can be calculated based on the measured concentration profiles.
原文 | ???core.languages.en_GB??? |
---|---|
頁面 | 197-202 |
頁數 | 6 |
出版狀態 | 已出版 - 1997 |
事件 | Proceedings of the 1997 27th Congress of the International Association of Hydraulic Research, IAHR. Part D - San Francisco, CA, USA 持續時間: 10 8月 1997 → 15 8月 1997 |
???event.eventtypes.event.conference???
???event.eventtypes.event.conference??? | Proceedings of the 1997 27th Congress of the International Association of Hydraulic Research, IAHR. Part D |
---|---|
城市 | San Francisco, CA, USA |
期間 | 10/08/97 → 15/08/97 |