A simple, cost-effective sensor for detecting lead ions inwater using under-potential deposited bismuth sub-layer with differential pulse voltammetry (DPV)

Yifan Dai, Chung Chiun Liu

研究成果: 雜誌貢獻期刊論文同行評審

20 引文 斯高帕斯(Scopus)

摘要

This research has developed a simple to use, cost effective sensor system for the detection of lead ions in tap water. An under-potential deposited bismuth sub-layer on a thin gold film based electrochemical sensor was designed, manufactured, and evaluated. Differential pulse voltammetry (DPV) measurement technique was employed in this detection. Tap water from the Cleveland, OH, USA regional water district was the test medium. Concentrations of lead ion in the range of 8 × 10-7 M to 5 × 10-4 M were evaluated, showing a good sensitivity over this concentration range. The calibration curve for the DPV measurements of lead ions in tap water showed excellent reproducibility with R2 value of 0.970. This DPV detection system required 3–6 min to complete the detection measurement. A longer measurement time of 6 min was used for the lower lead ion concentration. The selectivity of this lead ion sensor was very good, and Fe III, Cu II, Ni II, and Mg II at a concentration level of 5 × 10-4 M did not interfere with the lead ion measurement.

原文???core.languages.en_GB???
文章編號950
期刊Sensors (Switzerland)
17
發行號5
DOIs
出版狀態已出版 - 5月 2017

指紋

深入研究「A simple, cost-effective sensor for detecting lead ions inwater using under-potential deposited bismuth sub-layer with differential pulse voltammetry (DPV)」主題。共同形成了獨特的指紋。

引用此