@inproceedings{1e5b974cc6a444e08db6d5726b8d50fb,
title = "A pseudo-flash ADC for large-channel-volume biomedical sensing applications",
abstract = "This paper describes an ADC architecture termed pseudo-flash ADC and intended for biomedical sensing applications. It features high conversion speed which is the same as that of flash ADC, but has significantly lower hardware implementation overhead. Designed in a 0.18-μm standard CMOS technology in accordance with a specification of 250 KSamples/s and 6-bit resolution, the proposed ADC architecture consumes a total of nearly 290 μW under the nominal supply voltage of 1.8 V, without the requirement of a large number of comparators as compared with the conventional flash ADC architecture.",
author = "Gong, {Cihun Siyong Alex} and Lu, {Jyun Wei} and Yao, {Kai Wen} and Tsai, {Jr Yu} and Shiue, {Muh Tian}",
year = "2008",
doi = "10.1109/EDSSC.2008.4760722",
language = "???core.languages.en_GB???",
isbn = "9781424425402",
series = "2008 IEEE International Conference on Electron Devices and Solid-State Circuits, EDSSC",
booktitle = "2008 IEEE International Conference on Electron Devices and Solid-State Circuits, EDSSC",
note = "2008 IEEE International Conference on Electron Devices and Solid-State Circuits, EDSSC ; Conference date: 08-12-2008 Through 10-12-2008",
}