Test results of the L3 precision muon detector

B. Adeva, M. Aguilar-Benitez, A. Aloisio, M. G. Alviggi, D. Antreasyan, L. Baksay, U. Becker, J. Berdugo, G. J. Bobbink, J. G. Branson, C. Burgos, J. D. Burger, D. Campana, F. Carbonara, M. Cerrada, Y. H. Chang, M. L. Chen, G. Chiefari, N. Colino, E. DragoP. Duinker, I. Duran, F. Erné, R. Fabbretti, M. Fabre, S. Feher, S. S. Gau, M. Gettner, E. Gonzalez, H. van der Graaf, D. Güsewell, F. G. Hartjes, V. Innocente, B. N. Jin, A. König, S. Lanzano, J. M. LeGoff, X. Leijtens, L. Li, S. Lokos, C. Mana, L. Martinez, G. G.G. Massaro, Y. F. Mao, R. Magahiz, P. McBride, L. Merola, M. Napolitano, H. Onvlee, G. Paternoster, S. Patricelli, Y. Peng, O. Prokofiev, J. M. Qian, P. Razis, L. Romero, J. A. Rubio, H. Rykaczewski, J. Salicio, K. Schetkovsky, P. Schmitt, C. Sciacca, P. G. Seiler, V. Souvorov, K. Strauch, C. Timmermans, S. Volkov, J. H. Wang, Q. F. Wang, Z. M. Wang, T. Wenaus, M. White, R. Wilhelm, C. Willmott, B. Wyslouch, F. Y. Xi, B. Z. Yang, C. G. Yang, Q. Y. Yang, C. H. Ye, S. C. Yeh, C. R. Zabounidis, Z. P. Zhang

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

The L3 detector is designed to measure the muon momentum with a 2% resolution at p = 45 GeV/c. We discuss here the systems we developed to reach the required accuracy and control the mechanical alignment at running time. We also report on the test done on the muon spectrometer with UV lasers and cosmic rays.

Original languageEnglish
Pages (from-to)335-341
Number of pages7
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume289
Issue number3
DOIs
StatePublished - 15 Apr 1990

Fingerprint

Dive into the research topics of 'Test results of the L3 precision muon detector'. Together they form a unique fingerprint.

Cite this