Abstract

We checked the performance of undoped BGO crystals under extremely high dose conditions (dosage up to 88 Mrad). The light outputs of the crystals drop by approx. 30% after receiving 10 Mrad of γ-ray dose but remain stable throughout the rest of the test. The self-recovery behavior of BGO under 20 Mrad has also been studied. The reduced variation in light output from pre-radiated BGOs, together with a fixed recovery limit, indicate that a pre-radiation process may be helpful to stabilized the BGO performance in a low dose environment.