Fly ash generated from municipal waste incineration (MWI) contains various toxic substances, and it has to be properly treated before disposal or reuse. Water washing and thermal pyrolysis can improve the destruction efficiency of PCDD/Fs in fly ash generated from municipal solid waste incinerators. Since sulfur oxides and nitrogen compounds generated by the heating of the sewage sludge poison the catalytic active sites for PCDD/Fs formation on fly ash surface, co-pyrolysis of fly ash with sewage sludge effectively inhibits precursor formation and de novo synthesis reaction, resulting in the great reduction of PCDD/F formation. The results of the pyrolysis at 350 °C show that the PCDD/Fs removal efficiencies based on mass concentration are over 99%. The results at 350 °C of different reaction times show that the reaction time of 10 min is sufficient to reach the European End of Waste criteria (≤ 20 pg TEQ/g) when the ratio of fly ash/sewage sludge is controlled at 1:1.

Original languageEnglish
Pages (from-to)39432-39438
Number of pages7
JournalEnvironmental Science and Pollution Research
Volume31
Issue number27
DOIs
StatePublished - Jun 2024

Keywords

  • De novo inhibition
  • Fly ash
  • PCDD/Fs
  • Pyrolysis
  • Sewage sludge