Bone defect detection on dental osseointegration using structural mode shape

Y. Sh Hsieh, J. Z. Chen, Ch S. Chen, S. Y. Lee, M. Ch Pan

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

This study aims to assess clinical bone defects between an implant and jaw bone after dental implantation by examining the mode shape of structures. Different severity of bone defects was evaluated through structure resonant frequencies and their corresponding mode shapes of the implant and jaw bone by using both numerical analysis and experimentation. This study consists of two parts. First, the assumption of two kinds of boundary conditions, bonding and rubbing, was applied to simulate osseointegration in the clinical dentistry and the in-vitro bone defect model, respectively, in finite element analysis. Natural frequencies and their mode shapes of the implant/jaw were computed by the modal analysis. During the harmonic analysis, the response displacements versus frequency of implant in the buccolingual and mesiodistal directions were defined. Secondly, the structural resonant frequencies were measured by a procedure of acoustic excitation and displacement response, and then this result was compared with using the detection of an Osstell mentor. The simulation results show that the structure local mode corresponding high-frequency resonance can be used to examine bone imperfection remarkably. Limited by extremely tiny response displacement, measuring dynamic range of the capacitive displacement sensor, the acoustic excitationdisplacement response measurement can only acquire the structure global mode of the mandible corresponding to low-frequency resonance. Additionally, the Osstell mentor can assess bone defects effectively. Therefore, the above-mentioned simulations and experimental results prove that the local mode is promising to evaluate the defect severity of the dental-implantation osseointegration.

Original languageEnglish
Title of host publication24th Conference on Mechanical Vibration and Noise
PublisherAmerican Society of Mechanical Engineers (ASME)
Pages201-205
Number of pages5
EditionPARTS A AND B
ISBN (Print)9780791845004
DOIs
StatePublished - 2012
EventASME 2012 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2012 - Chicago, IL, United States
Duration: 12 Aug 201212 Aug 2012

Publication series

NameProceedings of the ASME Design Engineering Technical Conference
NumberPARTS A AND B
Volume1

Conference

ConferenceASME 2012 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2012
Country/TerritoryUnited States
CityChicago, IL
Period12/08/1212/08/12

Keywords

  • Dental implantation
  • Irregular osseointegration
  • Mode shape

Fingerprint

Dive into the research topics of 'Bone defect detection on dental osseointegration using structural mode shape'. Together they form a unique fingerprint.

Cite this