TY - JOUR
T1 - A single-use, disposable iridium-modified electrochemical biosensor for fructosyl valine for the glycoslated hemoglobin detection
AU - Fang, Lei
AU - Li, Wei
AU - Zhou, Yan
AU - Liu, Chung Chiun
PY - 2009/3/28
Y1 - 2009/3/28
N2 - A single-use, disposable biosensor prototype of fructosyl valine (FV) was developed in this study. FV was a model compound for the glycosylated hemoglobin (HbA1c) detection and the measurement of HbA1c level was important for the long-term management of diabetic patients. Therefore, the detection of FV would be important for diabetic patient management as a means for HbA1c biosensing, particularly if this biosensor could be a single-use, disposable and manufactured cost effectively. This single-use, disposable FV electrochemical biosensor was fabricated using thick film screen-printing technique. Iridium nano-particle catalysts were incorporated in the carbon-based working and counter electrodes enhancing the performance of the biosensor for the FV detection. The enzyme fructosyl amine oxidase (FAO, EC 1.5.3, 0.45 U mg-1 of solid from recombinant Escherichia coli) was immobilized on the working electrode of the biosensor prototype. This biosensor operated at a relatively low electrochemical potential (+0.25 V versus Ag/AgCl) at ambient temperature to detect the enzymatically produced H2O2 from FV. This biosensor responded well to the FV level in a physiological range and the sensor output could be modeled by the Michaelis-Menton relationship. Thus, this biosensor prototype could be used effectively as the basis for a single-use, disposable HbA1c detection for diabetic patient management.
AB - A single-use, disposable biosensor prototype of fructosyl valine (FV) was developed in this study. FV was a model compound for the glycosylated hemoglobin (HbA1c) detection and the measurement of HbA1c level was important for the long-term management of diabetic patients. Therefore, the detection of FV would be important for diabetic patient management as a means for HbA1c biosensing, particularly if this biosensor could be a single-use, disposable and manufactured cost effectively. This single-use, disposable FV electrochemical biosensor was fabricated using thick film screen-printing technique. Iridium nano-particle catalysts were incorporated in the carbon-based working and counter electrodes enhancing the performance of the biosensor for the FV detection. The enzyme fructosyl amine oxidase (FAO, EC 1.5.3, 0.45 U mg-1 of solid from recombinant Escherichia coli) was immobilized on the working electrode of the biosensor prototype. This biosensor operated at a relatively low electrochemical potential (+0.25 V versus Ag/AgCl) at ambient temperature to detect the enzymatically produced H2O2 from FV. This biosensor responded well to the FV level in a physiological range and the sensor output could be modeled by the Michaelis-Menton relationship. Thus, this biosensor prototype could be used effectively as the basis for a single-use, disposable HbA1c detection for diabetic patient management.
KW - Diabetic patient management
KW - Fructosyl valine
KW - Glycosylated hemoglobin
KW - HbA biosensor
KW - Thick film screen-printed electrode
UR - http://www.scopus.com/inward/record.url?scp=60549116664&partnerID=8YFLogxK
U2 - 10.1016/j.snb.2008.09.045
DO - 10.1016/j.snb.2008.09.045
M3 - 期刊論文
AN - SCOPUS:60549116664
SN - 0925-4005
VL - 137
SP - 235
EP - 238
JO - Sensors and Actuators, B: Chemical
JF - Sensors and Actuators, B: Chemical
IS - 1
ER -