TY - JOUR
T1 - A new gas chromatography method for continuous monitoring of non-methane hydrocarbons as an analogy of volatile organic compounds in flue gas
AU - Wang, Chieh Heng
AU - Hua, Hsi Che
AU - Lin, Wei Chuan
AU - Hsieh, Hsin Cheng
AU - Wang, Jia Lin
N1 - Publisher Copyright:
© Taiwan Association for Aerosol Research.
PY - 2018/12
Y1 - 2018/12
N2 - A new on-line method of monitoring the total non-hydrocarbons (TNMHC) from the flue or waste gas of stationary sources, which significantly improves upon the current method commonly used in both Taiwan and China, is described. The major problem with the current method is that higher-boiling-point compounds in the waste gas saturate porous materials within the molecular-sieve column used to immobilize TNMHC and elute methane, which sabotages the fixability of TNMHC and leads to false methane and TNMHC readings during continuous monitoring. Our new method effectively circumvents this issue by incorporating a dual-column and back-flush design, rendering it a true gas chromatography (GC) method. Applying this GC method, light hydrocarbons, such as methane, ethane, and propane, can be fully separated by the dual column set. After methane enters the analytical column, a reverse carrier flow immediately back-flushes the pre-column while keeping the analytical column flowing forward by a second flow of the carrier gas for eluting methane. The field application, particularly upon repeated analyses of flue gas laden with complex and elevated levels of volatile organic compounds (VOCs), has shown that self-cleaning by back-flush is necessary when operating at a constant oven temperature.
AB - A new on-line method of monitoring the total non-hydrocarbons (TNMHC) from the flue or waste gas of stationary sources, which significantly improves upon the current method commonly used in both Taiwan and China, is described. The major problem with the current method is that higher-boiling-point compounds in the waste gas saturate porous materials within the molecular-sieve column used to immobilize TNMHC and elute methane, which sabotages the fixability of TNMHC and leads to false methane and TNMHC readings during continuous monitoring. Our new method effectively circumvents this issue by incorporating a dual-column and back-flush design, rendering it a true gas chromatography (GC) method. Applying this GC method, light hydrocarbons, such as methane, ethane, and propane, can be fully separated by the dual column set. After methane enters the analytical column, a reverse carrier flow immediately back-flushes the pre-column while keeping the analytical column flowing forward by a second flow of the carrier gas for eluting methane. The field application, particularly upon repeated analyses of flue gas laden with complex and elevated levels of volatile organic compounds (VOCs), has shown that self-cleaning by back-flush is necessary when operating at a constant oven temperature.
KW - Continuous emission monitoring system (CEMS)
KW - Flue gas
KW - Volatile organic compounds (VOCs)
UR - http://www.scopus.com/inward/record.url?scp=85063662307&partnerID=8YFLogxK
U2 - 10.4209/aaqr.2018.05.0193
DO - 10.4209/aaqr.2018.05.0193
M3 - 期刊論文
AN - SCOPUS:85063662307
VL - 18
SP - 2913
EP - 2921
JO - Aerosol and Air Quality Research
JF - Aerosol and Air Quality Research
SN - 1680-8584
IS - 12
ER -